[Skip Header and Navigation] [Jump to Main Content]
Home

Secondary Links

  • Publications
  • Centers
  • Media
  • Important Forms
  • Contact Us

Languages

  • العربية
  • English

Primary Links

  • Home
  • About
  • Programs
  • Faculty Achivements
  • Photo Gallery
  • Quality Unit
  • Students
Home

Recreation Centre

Academic Year: 
2013
Supervisors: 
Muayed A. Salhab
Students: 
Bayan Hudhud
Shayma’ Aljurf
Thekra Shehada
Department: 
Building Engineering
Files: 
application/vnd.openxmlformats-officedocument.presentationml.presentation iconal_mashroo3.pptx

AN-NAJAH NATIONAL UNIVERSITY

BUILDING ENGINEERING DEPARTMENT

Recreation Centre

•        

 Contents

•        

Project Background

•        

Architectural Plan.

•        

Mechanical Plan.

•        

Structural Plan

•        

Environmental Analysis

•        

Electrical Plan

 

•        

Project Background

The project is designing of Recreation Centre in Nablus, The building contains of three floors, basement, ground floor, anf first floor.

 

•        

Environmental  Analysis

The  Environmental Analysis has been mad by using the  Autodesk Building Analysis Program (ECOTECT)

Sun Path In Sumner Solstice (21 June) 

 

•        

Curtin Wlls of the Swimming pool :

•         

Dark colored .

•         

Thickness more than 4 mm

•         

Reflection factor of about 75% of the wall area.

 

 

•         

Electrical Design

Lighting

Power

Low current and fire resisting

 

•        

Structural design

Formulation the model into 3D using analysis program (SAP2000.v14.0)

The required materials which can satisfy the serviceability and safety of construction is:

 

The cylinder compressive strength at 28days, f'c=250kg/cm2

The yield strength of steel bars, fy=4200kg/cm2 (high strength steel).

 

•        

Designs:

Dynamic Design                                    Preliminary Design

Design slab                                            Design of beam

Column design                                     Design of Foundation

Design of stair case                             Design of pool

 

•        

Structural Model Verification

Check Equilibrium

Compatibility Check

Check Stress Strain Relationship

Modal Mass Participation Ratio (MMPR) Check

 

•        

Types of Footings:

Isolated(single footings):

It is used to support single columns; they are squared, rectangular, or circular shape. Footing maybe uniform thickness or have a sloped top, this is one of the most economical types of footings, and it used when columns are spaced at relatively long distance. The most commonly used are square footings with uniform thickness.

 

 

•        

Steel design

    Steel structures have many uses and applications in our life, for example:

Industrial/Parking structures “Frames”

Joists/Trusses

High rise buildings

Girder bridges

Truss bridges

Cable stayed & suspended bridges

 

Once we finish modeling on SAP2000, three checks must be made:

( checks will be performed on the 2D middle truss of length 21.5 )

Compatability: by inspection, the compatability was satisfied.

Equilibrium: the sum of forces acting must equal the sum of the forces on the supports in the same direction.

 

•        

Design of connections

     The maximum tension force in the bottom members = 445.1 KN which will be considered for the design.(the connection ID is 52)

 

 

©2012 An-Najah National University|Faculty Of Engineering | P.O. Box: 7 | Nablus, Palestine | Phone: +970 (9) 2345113 Ext:2253 | Fax: +970 (9) 2345982 | email: [email protected]